Appendix, Technical, Specifications – Adtec digital DPI-1200 (version 01.04.08U) Manual User Manual
Page 56: Appendix d - technical specifications

Select SCTE30 Splice Response Messages
Resul
t
Result Name
Description
100
Successful Response
104
Invalid/Unknown Channel
Name
Possible configuration error
105
Invalid Physical Connection
Possible configuration error
108
Splice Failed – Unknown Failure
110
No Insertion Channel Found
This error shall be returned if the Insertion
Channel is missing at the start of a splice.
111
No Primary Channel Found
This error shall be returned if the Primary
Channel is missing at the Splice-in or Splice-out
times.
112
Splice_Request Was Too Late
The Splice_Request message was not received
early enough (3 seconds) for the Splicer to
initiate the splice.
113
No Splice Point Was Found
The Splicer was unable to find a valid point to
splice into the Primary
Channel
Appendix D - Technical Specifications
Inputs
10/100 base-T Ethernet
Connector: 8 pin RJ45 x1
Gigabit Ethernet
Connector: 8 pin RJ45 x1
NAS Compliant Storage Interface
DTMF/GPI
Twelve GPI or GPO
Twelve DTMF Input (-10 to +0 dB)
Outputs