Appendix, Understanding, System – Adtec digital DPI-1200 (version 01.04.08U) Manual User Manual
Page 50: File, Appendix c - understanding the dpi system log file

MDI or chaining port- if this port was used, move the
patch cord to a non- MDI or -chaining port.
Channel indicators are neither red
or green
The channel has been administratively disabled or
feature locked. Re-enable the port via the front panel
or command API, if unlocked
Channel indicators flash red and
yellow
The DPI has lost communication with the splicer for
that channel. Check the splicer configuration for that
channel and the splicer interface for issues with the
output.
Channel indicator flashes red during
insert and then goes back to green
There is a discrepancy between the splicer and the
DPI. Check the time sync and media being used.
Verification files show a status of
0013 “Time Out”
Check the timing sync between the DPI and the
splicer. Check the media to be inserted for proper
encoding and audio formats to the stream
Verification files show a status of
0023 “No Cue”
Check cue method being used. If DTMF or GPI, check
the connector cable running between the receiver
and DPI. If SCTE35, check the insertion stream and
splicer configuration to make sure that it is available
and used
NTP Clock will not sync to address
Check the NTP server to make sure that it is a Linux
stratum server and the time server daemon is
running.
Appendix C - Understanding the DPI System Log File
System Operators
CHNLMGR – Channel Manager
CMDL – Command Log
FTPC – File Transfer Protocol Client
MIRROR – Mirror Client
SCHED – Schedule Daemon
STRM – Stream Manager
TRGRD – Trigger Daemon