9.4 Selecting between “set-point ramp” and “set-point step”

Set-points always refer to the start of a program section, i.e., at the beginning of each program section the

entered set-point is targeted. During program section operation, the temperature or humidity gradually

passes to the set-point entered for the next program section.
By appropriate planning of the program section timing, you can enter all kinds of temperature and humidity

transitions:

Gradual temperature / humidity changes “set-point ramp”
The set-point changes its value gradually while proceeding from one program section to the next one

during the programmed section length. The actual temperature or humidity value (X) follows the con-

tinually moving set-point (W) at any time.

Program sections with constant temperature / humidity
The initial values of two subsequent program sections are identical; so the temperature or humidity

remains constant during the whole time of the first program section.

Sudden temperature / humidity changes “set-point step”
Steps are temperature or humidity changes (ramps) that occur during a very short interval. A section

with a different set-point follows two program sections with an identical set-point. If the duration of this

transitional program section is very short (minimum entry 1 sec), the temperature or humidity change

will proceed rapidly within the minimum amount of time.

Figure 14: Possible temperature or humidity transitions


The following chapter offers examples of programming a “set-point ramp” and a “set-point step”.

9.5 Program entry as “set-point ramp” or as “set-point step”

In order to avoid incorrect programming, we recommend plotting both the temperature and humidity pro-

files (chart templates in chap. 9.11 and 9.12) and entering the values into a table (templates in chap 9.13

and 9.14).
The controller provides 8 operation lines (non-functional with standard unit) that can be activated or de-

activated for each program section.

01

02

03

04

05

06

07

08

09

W