Operation diagnosis
PSSnet SHL - Basic Configuration
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
9.3 Out-of-band signaling
161
9.3.1 Controlling the signal contact
With this mode you can remotely control every signal contact individually.
Application options:
X
Simulation of an error during SPS error monitoring.
X
Remote control of a device via SNMP, such as switching on a camera.
9.3.2 Monitoring the device status via the signal
contact
The "Device Status" option enables you, like in the operation monitoring, to
monitor the device state
(see on page
157
„Monitoring
the
device
status“)
via
the signal contact.
Select the Diagnostics:Signal Contact 1/2) dialog.
In the "Mode Signal contact" frame, you select the "Manual setting"
mode to switch the contact manually.
Select "Opened" in the "Manual setting" frame to open the contact.
Select "Closed" in the "Manual setting" frame to close the contact.
enable
Switch to the Privileged EXEC mode.
configure
Switch to the Configuration mode.
signal-contact 1 mode manual Select the manual setting mode for signal contact
1.
signal-contact 1 state open
Open signal contact 1.
signal-contact 1 state closed Close signal contact 1.