Pilz PSSnet SHL 8T MRP User Manual
Page 141

Network load control
142
8.6 VLANs
PSSnet SHL - Basic Configuration
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
X
T = with TAG field (T
=
tagged)
X
U = without TAG field (U
=
untagged)
In this example, tagged frames are used in the communication between
the transmission devices (uplink), as frames for different VLANs are dif-
ferentiated at these ports.
Terminal
Port
Port VLAN identifi-
er (PVID)
A
1
2
B
2
3
C
3
3
D
4
2
Uplink
5
1
Table 14: Ingress table for device on left
Terminal
Port
Port VLAN identifi-
er (PVID)
Uplink
1
1
E
2
2
F
3
3
G
4
2
H
5
3
Table 15: Ingress table for device on right
VLAN ID
Port
1
2
3
4
5
1
U
2
U
U
T
3
U
U
T
Table 16: Egress table for device on left
VLAN ID
Port
1
2
3
4
5
1
U
2
T
U
U
3
T
U
U
Table 17: Egress table for device on right