Pilz PSSnet SHL 8T MRP User Manual
Page 111

Network load control
112
8.2 Multicast application
PSSnet SHL - Basic Configuration
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
Parameter values
The parameters
– Max. Response Time,
– Send Interval and
– Group Membership Interval
have a relationship to each other:
Max. Response Time < Send Interval < Group Membership In-
terval.
If you enter values that contradict this relationship, the device then re-
places these values with a default value or with the last valid values.
Parameter
Protocol
Version
Value range
Default setting
Max. Response Time
1, 2
3
1-25 seconds
1-3598 seconds
10 seconds
Send Interval
1, 2, 3
2-3599 seconds
125 seconds
Group Membership Interval
1, 2, 3
3-3600 seconds
260 seconds
Table 7: Value range for
- Max. Response Time
- Send Interval
- Group Membership Interval