System monitor, 1 system monitor – Pilz PSSnet SHL 8T MRP User Manual
Page 15

Access to the user interfaces
16
1.1 System Monitor
PSSnet SHL - Basic Configuration
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
1.1 System Monitor
The system monitor enables you to
X
select the software to be loaded
X
perform a software update
X
start the selected software
X
shut down the system monitor
X
delete the configuration saved and
X
display the boot code information.
Opening the system monitor
Use the terminal cable (see accessories) to connect
– the V.24 socket (RJ11) to
– a terminal or a COM port of a PC with terminal emulation based on
VT100
(for the physical connection, see the "Installation" user manual).
Start the terminal program on the PC and set up a connection with the
device.
When you boot the device, the message
"Press <1> to enter System Monitor 1"
appears on the terminal.
Speed
9,600 Baud
Data
8 bit
Parity
none
Stopbit
1 bit
Handshake
off
Table 1: Data transfer parameters