Technical details
8
Technical details
8
8000
Technical details
Technical details
8-
8.1
Technical details
8100
Technical details
8-
][Technische Daten PSSu Analoge ST-Ein
Technical details
Application range
Standard
Module's device code
0301h
Number of ST input bits
64
Number of ST status bits
32
Support in system environment A
from ST firmware version for other head modules
7
from ST firmware version PSSu H S PN
1
from ST firmware version PSSu WR S IDN
4
Support in system environment B
from head module ST firmware version
1.0.0
Electrical data
Internal supply voltage (module supply)
Supply voltage range of module supply
4.8 - 5.4 V
Module's current consumption
53 mA
Module's power consumption
0.26 W
Periphery's supply voltage (periphery supply)
Voltage range
16.8 - 30.0 V
Module's current consumption with no load
10 mA
Module's power consumption with no load
0.24 W
Max. power dissipation of the module
0.50 W
Inputs
Number of analogue inputs
4
Type of analogue inputs
Voltage
Input range
0 .. 10 V (single-ended)
Resolution (without sign bit)
12 Bit
Max. continuous voltage
12 V
Input resistance (voltage input)
100 kOhm
Deviations from the measuring range limit value
Linearity error
0.05 %
Output variable error at 25° C
0.2 %
Temperature coefficient
0.0200 %/K
Max. measurement error during EMC test
1.0 %
Analogue input filter
RC filter
Cutoff frequency
130 Hz
Potential isolation between input and voltage for the inter-
nal module bus
yes
Potential isolation between input and periphery supply
yes
Times
Typ. processing time
1.0 ms
Environmental data
Climatic suitability
EN 60068-2-14, EN 60068-2-1, EN 60068-2-2,
EN 60068-2-30, EN 60068-2-78
Ambient temperature in accordance with EN 60068-2-14
0 - 60 °C
-40 - 70 °C coated version (-T)
Storage temperature in accordance with EN 60068-2-1/-2 -25 - 70 °C
-40 - 70 °C coated version (-T)
Climatic suitability in accordance with EN 60068-2-30,
EN 60068-2-78
93 % r. h. at 40 °C
Condensation
no
yes coated version (-T)