This chapter discusses many of the features used to manage the switch, and explains many concepts and
important points regarding these features. Configuring the Switch to implement these concepts is discussed in
detail in the next chapters.

Local Console Management

Local console management involves the administration of the Switch via a direct connection to the RS-232
DCE console port. This is an Out-Of-Band connection, meaning that it is on a different circuit than normal
network communications, and thus works even when the network is down.

The local console management connection involves a terminal or PC running terminal emulation software to
operate the Switch’s built-in console program (see Chapter 6, “Using the Console Interface”). Using the console

program, a network administrator can manage, control and monitor the many functions of the Switch.

Hardware components in the Switch allow it to be an active part of a manageable network. These components
include a CPU, memory for data storage, other related hardware, and SNMP agent firmware. Activities on the
Switch can be monitored with these components, while the Switch can be manipulated to carry out specific
tasks.

Diagnostic (Console) Port (RS-232 DCE)

Out-of-band management requires connecting a terminal, such as a VT-100 or a PC running terminal
emulation program (such as HyperTerminal, which is automatically installed with Microsoft Windows) a to
the RS-232 DCE console port of the Switch. Switch management using the RS-232 DCE console port is called
Local Console Management to differentiate it from management done via management platforms, such as D-

View, HP OpenView, etc.

The console port is set for the following configuration:

Baud rate:

9,600

Data width:

8 bits

Parity:

none

Stop bits:

1

Flow Control

none

Make sure the terminal or PC you are using to make this connection is configured to match these settings.
If you are having problems making this connection on a PC, make sure the emulation is set to VT-100 or
ANSI. If you still don’t see anything, try hitting + r to refresh the screen.