62.5

µµµµ

m

62.5

µµµµ

m

50

µµµµ

m

50

µµµµ

m

Modal bandwidth

(min. overfilled launch)

Unit: MHz*km

160

200

400

500

Operating distance

Unit: meters

220

275

500

550

Channel insertion loss

Unit: dB

2.33

2.53

3.25

3.43

1000BASE-LX Gigabit Module

Figure 3-10. One-port, 1000BASE-LX gigabit module

One- or two-port, rear-panel module.

Connects to a 1000BASE-LX device at full duplex.

Allows connections up to 5 km in length using single-mode fiber optic cable.

1000BASE-T Copper Gigabit Module

Figure 3-11. One-port, 1000BASE-T gigabit module

One- or two-port, rear-panel module.

Connects to 1000BASE-T devices at 1000M/full duplex, 100M/full duplex, 100M/half duplex, and Auto.

Supports Category 5+ or higher cable connections of up to 100 meters.