EXFO FastReporter 2 User Manual
Page 161

Working with OTDR Files
Post Processing Software
151
Setting and Applying OTDR/OTDR Bidir Reference as Template (FR2-FC Mode)
Use same wavelength for all measurements: to apply the same
wavelength to all measurements. If a file with multiple wavelength
files is used as a reference and the option is not selected, the
measurements will be compared to the same wavelength
(1310 nm with 1310 nm, 1550 nm with 1550 nm).
Remove events not present in reference: to remove the events
not present in the reference file from the selected files.
Apply reference spans start/end: to apply the reference
measurement’s spans to the selected files.
Apply manual measurement markers and zoomed area: to apply
the reference’s marker position and zoom to the selected files. If
the marker positions is outside the range of the trace destination,
the operation will be aborted and the destination trace keeps its
original zoom factor.
Note: You are notified when the zoom is not applied.
Note: This option is available only if the Markers option is enabled from View >
OTDR > Markers.
Copy documentation from reference (except Fiber ID): to apply
the documentation from the reference file to the selected files. The
documentation includes job ID, customer, company, operator A,
operator B, cable ID, location A, location B, and comments.
Copy reference events markers (a,A,B,b) position: to copy the
events markers (a, A, B, b) from the reference measurement to the
selected files.
Note: When an event marker position from the reference measurement cannot
be copied to the selected measurement due to length constrain or any other
reason, the application does not display any error message.
7. Click OK.