Echelon Neuron User Manual
Page 33
Neuron Tools Errors Guide
25
LID#
Description
68
The Micro Server does not support transceiver
configuration
This error can occur if you specify incorrect clocking details for the LonTalk
Interface Builder (the command-line interface for the LonTalk Interface
Developer utility). Check your preferences.
This error code applies only to a ShortStack Micro Server.
69
The Micro Server is not supported by the Micro Server database
This error can occur if you incorrectly specify the Micro Server for the
LonTalk Interface Builder (the command-line interface for the LonTalk
Interface Developer utility). Check your preferences.
This error code applies only to a ShortStack Micro Server.
70
Error loading the Micro Server database:
This error occurs upon a particular failure when loading the Micro Server
database, as detailed in the error message. Unless the error detail suggests
a different remedy, you should re-install the product and choose the Repair
option when prompted.
Also, temporarily remove any user-defined extensions to the Micro Server
database (that is, remove or rename the UserServers.xml file).
This error code applies only to a ShortStack Micro Server.
71
Clock multiplier
This error can occur if you specify an incorrect set of arguments for the
LonTalk Interface Builder command line interface (the command-line
interface for the LonTalk Interface Developer utility). Check your
arguments.
72
This error can occur if you specify an incorrect set of arguments for the
LonTalk Interface Builder command line interface (the command-line
interface for the LonTalk Interface Developer utility). Check your
arguments.
Note that the -clock parameter refers to the external clock, not the system
clock.
4001
An XIF file contains more fields than expected
Refer to the warning message for line # and filename. This might result in
an automatic downgrading of the device interface file to the version
supported by the FTXL or FTXL tools. Che
available updates.