LonTalk Interface Developer Errors (LID)
LID#
Description
62
Insufficient buffer space
The message includes the total number of bytes available for transceiver
buffers and how many additional bytes your selected configuration
requires.
This error occurs because you specified that the LonTalk Interface
Developer utility declare more buffers than the available memory space
within the device.
To avoid this error, supply or declare more RAM, or request fewer or
smaller buffers.
63
Malformed data:
Data
d
does not meet expectations
t
. For unmodified data, this error
condition should not occur.
Re-install the product, and choose the repair option when prompted.
64
Failure loading neuron.xml
The neuron.xml database, located in the Types folder within your local
LonWorks folder, is a central repository of data that describes the various
attributes and capabilities of Neuron Chips and Smart Transceivers. A
failure to load this database indicates a fundamental error.
Re-install the product, and choose the repair option when prompted.
65
The chosen clocking scheme (ID ) doesn't support external clock
clock multiplier of
This error indicates inconsistent and incorrect clocking specifications.
Verify your clocking-related preferences.
66
The Micro Server does not support clock multiplier
configuration
This error can occur if you specify incorrect clocking details for the LonTalk
Interface Builder (the command-line interface for the LonTalk Interface
Developer utility). Check your preferences.
This error code applies only to a ShortStack Micro Server.
67
The Micro Server does not support clock
This error can occur if you specify incorrect clocking details for the LonTalk
Interface Builder (the command-line interface for the LonTalk Interface
Developer utility). Check your preferences.
This error code applies only to a ShortStack Micro Server.