Echelon Neuron User Manual
Page 29
Neuron Tools Errors Guide
21
LID#
Description
35
Configuration parameters are in use, but no template file has been found
This might be the result of an earlier error. Delete all intermediate files.
Re-run the LonTalk Interface Developer utility in Trace verbosity mode and
carefully examine the LonTalk Interface Developer utility Summary
window to determine the root cause of the failure.
If the problem persists, contact Echelon technical support, submitting all
files produced by the LonTalk Interface Developer utility when running in
Trace verbosity level.
36
The program ID found in the XIF file seems malformed and cannot be used to
produce the niAppinit data
Use the LonTalk Interface Developer utility and the Standard Program ID
calculator to produce a good program ID record. Delete all intermediate
files. Re-run the LonTalk Interface Developer utility in Trace verbosity
mode and carefully examine the LonTalk Interface Developer utility
Summary window to determine the root cause of the failure.
If the problem persists, contact Echelon technical support, submitting all
files produced by the LonTalk Interface Developer utility when running in
Trace verbosity level.
37
Malformed communication parameters
This is an internal error, which only occurs as a result of an unrecognized
previous error.
This error code applies only to a ShortStack Micro Server.
38
Cannot calculate communication parameters
Refer to the error message for details of the failure cause. Delete all
intermediate files from the LonTalk Interface Developer project directory.
Re-run the LonTalk Interface Developer utility in Trace verbosity mode and
carefully examine the LonTalk Interface Developer utility Summary
window to determine the root cause of the failure.
If the problem persists, contact Echelon technical support, submitting all
files produced by the LonTalk Interface Developer utility when running in
Trace verbosity level.
This error code applies only to a ShortStack Micro Server.
39
Cannot locate Micro Server’s symbol file
Refer to the error message for the filename. A Micro Server has three
groups of files: image files that get loaded into the Smart Transceiver (.nei,
.nxe, or .nri extension), device interface files (.xif or .xfb extension), and
symbol files (.sym extension). All of these files must share the same base
name, and they must reside in the same location. This error describes a
problem in locating the symbol file. The expected name and location is
detailed in the error message.
This error code applies only to a ShortStack Micro Server.