4 - ratings & capacities – Dunkirk Excelsior EXB Series User Manual

Page 8

background image

8

GPH = U.S. Gallons per Hour

Mbh = 1000 Btu (British thermal units) per hour.

psi = Pounds per square inch

*MAWP = Maximum allowable working pressure. This low pressure oil fired hot water boiler is constructed and

hydrostatically tested for maximum working pressure of 65 psi in accordance with the latest revision of the A.S.M.E.

(American Society of Mechanical Engineers) Boiler and Pressure Vessel Code Section IV Standards for heating boilers.

AFUE= Annual Fuel Utilization Efficiency

Heating Capacity and AFUE based on 13.1% CO

2

(13.5% CO

2

at 0.95 GPH and 1.10 GPH), -0.02” w.c. draft in breech, and

# 1 smoke or less. Testing is done in accordance with U.S. DOE (Department of Energy) test procedure.

Heating Capacity indicates amount of heat available after subtracting losses up the stack. Remaining heat is available

to heat water. Small portion is heat from jacket and surfaces of boiler and this heat stays in structure. Net AHRI rating

represents portion of remaining heat applied to heat radiation or terminal units (i.e. finned tube baseboard, cast iron

radiators, radiant floor, etc.). Difference between Heating Capacity and Net AHRI Rating, called piping and pickup

allowance, establishes reserve for heating volume of water in system and offsetting heat losses from system piping. Net

AHRI ratings shown are based on piping and pickup factor of 15% in accordance with AHRI Standard as published by

Hydronics Institute.

Net AHRI rating of boiler selected should be greater than or equal to calculated peak heating load (heat loss) for building

or area(s) served by boiler and associated hot water heating systems. Consult manufacturer before selecting boiler for

installations having unusual piping and pickup requirements.

4 - RATINGS & CAPACITIES

Table 1 RATINGS & CAPACITIES

OIL-FIRED HOT WATER BOILERS

Number

of

Sections

Firing

Rate

[GPH]

Input

[Mbh]

Heating

Capacity

[Mbh]

Net

AHRI

Rating

[Mbh]

*MAWP

Water

[psi]

AFUE

[%]

Min. relief

Valve

Capacity

[Mbh]

Max.

Water

Temp

[°F]

Chimney

Liner Size

Round

[Inches]

Chimney

Liner

Size

[Square

Inches]

Flue

Size

[Inches]

4

0.75

105

91

79

65

86.0

91

250

6

6 3/4

5

4

0.95

133

114

99

65

85.0

115

250

6

6 3/4

5

4

1.10

154

132

115

65

84.0

132

250

6

6 3/4

5

5

1.00

140

122

106

65

86.5

122

250

6

6 3/4

5

5

1.15

161

139

121

65

85.0

139

250

6

6 3/4

5

5

1.35

189

161

140

65

84.0

161

250

7

6 3/4

5

6

1.30

182

159

138

65

86.5

159

250

6

6 3/4

5

6

1.45

203

176

153

65

85.0

176

250

7

6 3/4

5

6

1.65

231

198

172

65

84.0

198

250

7

6 3/4

5

7

1.65

231

201

175

65

86.0

201

250

7

6 3/4

6

7

1.80

252

217

189

65

85.0

217

250

7

6 3/4

6

7

1.90

266

228

198

65

84.0

227

250

8

6 3/4

6