Fresh Air Duct Capacities For Ducts Supplying Fresh Air To Boiler In Tightly Constructed Houses

Table 3 - FRESH AIR DUCT CAPACITIES

THROUGH LOUVERS

Fresh Air

Duct Size

¼” Mesh

Screen

Wood

Louvers

Metal

Louvers

(Btuh)*

(Btuh)*

(Btuh)*

3 ½” x 12”

144,000

36,000

108,000

8” x 8”

256,000

64,000

192,000

8” x 12”

384,000

96,000

288,000

8” x 16”

512,000

128,000

384,000

*Btuh = British Thermal Units per hour based on

opening covered by ¼” mesh screen , wood lou-

vers, or metal louvers.

Figure 4 - Fresh Air Openings

7 - FRESH AIR FOR COMBUSTION