beautypg.com

Dunkirk Excelsior EXB Series User Manual

Page 49

background image

49

TABLE 14a: BECKETT DIRECT VENT PRELIMINARY BURNER SETTINGS

Boiler

Model

Head

Type

Insertion

Depth

Firing

Rate

[GPH]

Combus-

tion liner

Nozzle

Mfr.

Nozzle

Type

Pump

Pressure

[PSI]

Air

Setting

Pressure

Switch

Setpoint

Rated

AFUE

Efficiency

[%]

4075

6 Slot

2.5"

0.75

Oval

Delavan 0.60x60B

150

1.5

0.65" WC

86.0

4095

6 Slot

2.5"

0.95

Oval

Hago

0.75x60B

155

4.0

0.65" WC

85.0

5100

6 Slot

2.5"

1.00

None

Delavan 0.75x45B

175

4.0

0.85" WC

86.5

5115

6 Slot

2.5"

1.15

V5

Hago

1.00x60B

140

1.8

0.85" WC

85.0

5135

6 Slot

2.5"

1.35

V5

Delavan 1.10x60B

150

2.5

0.85" WC

84.0

6130

9 Slot

2.5"

1.30

V6

Danfoss 1.00x45B

175

2.0

0.65" WC

86.5

Timings

Pre-purge

15 seconds

Post-Purge

2 minutes

17 - OIL BURNER, NOZZLE, & AIR SETTINGS

Table 14 - Beckett NX (Direct Vent) Preliminary Burner Settings

TABLE 14b: BECKETT/ECR PART NUMBERS

Boiler

Model

Beckett

Oil Burner

Model

ECR Oil Burner

Part Number

4075

NX70LC

240007531

4095

NX70LC

240009393

5100

NX70LC

240007532

5115

NX70LF

240009395

5135

NX70LF

240009396

6130

NX70LD

240007533

Burner settings provided are for initial startup only. Final adjustments must be made using combustion test