beautypg.com

Dunkirk Excelsior EXB Series User Manual

Page 51

background image

51

Table 16: RIELLO 40BF DIRECT VENT PRELIMINARY BURNER SETTINGS

Boiler Model

Head

Type

Inser-

tion

Depth

Firing

Rate

[GPH]

Com-

bustion

Liner

Nozzle

Mfr.

Nozzle

Type

Pump

Pres-

sure

[PSI]

Head

Setting

Air

Setting

Pressure

Switch

Setpoint

Rated

AFUE

Efficiency

[%]

4075

Reverse

2.75"

0.75

Oval

Delavan 0.65x60W

150

3

5.0

0.25" WC

86.0

4095

Standard

1.75"

0.95

Oval

Delavan 0.75x90B

175

1

4.0

0.25" WC

85.0

4110

Standard

1.75"

1.10

Oval

Delavan 1.00x90B

125

2

5.0

0.25" WC

84.0

5100

Standard

2.75"

1.00

None

Delavan 0.75x60B

175

1

5.0

0.80" WC

86.5

5115

Standard

1.75"

1.15

None

Delavan 1.00x80B

130

2

5.8

0.80” WC

85.0

5135

Standard

1.75"

1.35

None

Delavan 1.20x80B

125

4

5.8

0.80” WC

84.0

6130

Standard

2.75"

1.30

V6

Delavan 1.00x45B

175

2

8.0

0.90" WC

86.5

Timings
Pre-purge

12 seconds

Post-Purge

45 seconds

17 - OIL BURNER, NOZZLE, & AIR SETTINGS

Table 16 - Riello 40BF (DIRECT VENT) Preliminary Burner Settings

Burner settings provided are for initial startup only. Final adjustments must be made using combustion test

instruments.

Boiler

Model

Riello

Oil

Burner

Model

ECR Oil Burner

Part Number

4075

40BF3

240007528

4095

40BF5

240009407

4110

40BF5

240009408

5100

40BF5

240007529

5115

40BF5

240009409

5135

40BF5

240009410

6130

40BF5

240007530