72 motion control theory – ADLINK PCI-8258 User Manual
Page 86
72
Motion Control Theory
• Signal direction
These signal logic may be inverted by software. Relevant axis
parameters are listed below:
• Board parameter
• Board parameter
• Filter
This controller features filters to screening out High-Frequency
Noise against motion control I/O to prevent abnormal motion
control action caused by external noise. The filter is defaulted
at ON status.
Param. No.
Define symbol
Description
00h (0)
PRA_EL_LOGIC
PEL/MEL input logic
01h (1)
PRA_ORG_LOGIC
ORG input logic
04h (4)
PRA_ALM_LOGIC
Set ALM logic
05h (5)
PRA_ZSP_LOGIC /
PRA_INP_LOGIC
Set INP logic
06h (6)
PRA_EZ_LOGIC
Set EZ logic
Param. No.
Define symbol
Description
Value
Default
00h (0)
PRS_EMG_LOGIC
EMG input logic 0 : Not inverse
1 : Inverse