8 svon output, Svon output, Figure 3-9 – ADLINK AMP-208C User Manual
Page 65: Servo-on signal connection example
Signal Connection
51
AMP-204C/AMP-208C
3.8
SVON Output
AMP-204C / AMP-208C provides 4/8 servo-on output channels
and utilize the servo-on signal to enable servo drive for pulse or
analog commands input. If there is abnormality is encountered
during movement, the AMP-204C / AMP-208C turns off this signal
automatically and stops all motion control commands. See below
for corresponding pins of servo-on signal output on DIN-825-GP4:
• Signal connection diagram:
Figure 3-9: Servo-on signal connection example
CMAx / CMPx
Pin No (x=1~4)
Signal Name
(n=1~4)
Description
Axis #
1
SVON(n)
Servo-on output
1~4
NOTE
NOTE
AMP-208C requires two DIN-825-GP4 for eight axes motion
control functions
# 1 controls axes 1 ~ 4 and #2 controls axes 5 ~ 8