1, selecting upper/lower limit comparison, 2,2. condition formula for comparison, Selecting upper/lower limit comparison – A&D Weighing Indicator AD-4329 User Manual
Page 39: Condition formula for comparison
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/726023/39/background.png)
9.2.1,
Selecting Upper/Lower Limit Comparison
step 1 Press the lOperate/Standbyl key to turn the display off.
F-Function mode
Press and hold the iMOPEl key and press the
Operate/Standbvl key to enter the F-function mode.
(upper/lower limit comparison).
Comparator function
Step 2 Select
F~^0
F-Vo ;
Upper/lower limit comparison
Step 3 Select comparison mode at
F-^ I
using the foilowing keys.
Step 4 Turn the display off using the lOperaie/Standbyi key.
Reference
F
"c’u
0
Not used
F-гo /
Upper/lower limit comparison.
F-’c'u
(?
Setpoint comparison
F~PI
Comparator mode
F-Pl
0
Ail data, Always
F~PI
/
Stable data
F-Pt P
Data exceeding +5d
F-p 1 J
Stable data exceeding f5d
F-Pl
4
Data exceeding -5d to -fSd
F-гl 5
Stable data exceeding -5d to +5d
A ! key.. ..The key to select a parameter.
Comparator mode
1
----------- ---- ______
key.. ..The key to store the parameter.
F-ei p
Data exceeding -^50
Display off
9.2,2.
Condition formula for Comparison
Comparison is performed based on the foilowing formula.
state Name
Condition Formula
HI (Over)
Upper limit value < Display value
OK (GO)
Lower limit value ^ Display value ^ Upper limit value
,,,,LO,,iynder)__
Display value < Lower limit value
□ The decimal point is not considered. Example: If the upper limit value is 10.0, input 100.
□ These parameters are stored in the EEPROM, and are not lost even if the AC
power is disconnected,
□ When the display value becomes an over load (positive over), HI (over) is outout.
When the display value becomes an under load (negative over), LO (under) is output.
□ The upper limit value and lower limit value can be set to a negative value.
□ This function compares the upper limit value first.
□ This function does not check the relation of upper limit value and lower limit value.
AD-4329 Weighing Indicator