System Messages and Beep Codes

C-3

Parity check 2

nnnn

A parity error was found in
the I/O bus at address nnnn.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

Real time clock

error

The CMOS battery that
supports data stored in
NVRAM may be dead.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

Shadow RAM

failed at off-

set: nnnn

Shadow RAM failed at
address nnnn.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

CMOS battery is

dead—Replace

and run Setup

The CMOS battery is dead.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

System cache

error—cache

disabled

The primary cache internal to
the microprocessor has
failed.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

System CMOS

checksum bad—

run Setup

The BIOS has been updated.

CMOS has been corrupted or
modified, possibly by an
application program that
changes data stored in
CMOS.

Reboot the computer and press as soon as
you see the Dell logo screen to enter the Setup
program and reconfigure the system. If the prob-
lem persists, call Dell for technical assistance. (For
instructions, see Chapter 5, “Getting Help.”)

System RAM

failed at off-

set: nnnn

System RAM failed at
address nnnn in the 64-KB
block at which the error was
detected.

Call Dell for technical assistance. (For instructions,
see Chapter 5, “Getting Help.”)

System timer

error

A chip on the system board
may be malfunctioning.

Run the System Board Devices device group
and the Keyboard Controller Test in the Dell
Diagnostics. (For instructions, see “Running the
Dell Diagnostics” found later in this chapter.)

Table C-1. System Error Messages (continued)

Message

Cause

Action

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary in the system Help.