Auger/Impeller - Discharge Chute

I

6.11 Chute Crank Adjustment

(Models with crank mounted to

left handlebar)

Loosen nut securing worm clevig to bracket.

Position worm gear with siight ciearance be­

tween worm gear and discharge chute gear
teeth, and tighten nut on bracket.

Lubricate discharge chute gear teeth and
lower base of discharge chute with oil and
move chute from side to side to see that it
moves freely.

6.12 Chute Crank Adjustment
(Models with crank through

handlebar panel)

The two brackets that attach flat gear to
discharge chute are slotted for adjustment.
Adjust so that pinion gear and flat gear mesh
together smoothly and tighten hardware.

1. Discharge Chute Gear Teeth
2. Worm Clevis
3. Nut

4. Discharge Chute
5. Worm Gear

Figure 6-11: Discharge Chute Adjustment

(Models with crank mounted to left

handlebar)

6-9