Page 42
Fig. 43 - Verification Needed
Notes –
• Once you change one of these safety-related
parameters, you
must finish the verification
process for the group that includes the parameter,
or the control system will not let the boiler
operate. You can wait to do the verification until
you have changed parameters in other groups,
but before you return the boiler to service, you
have to do the verification for all of the groups you
changed.
• At the end of the verification process, you
must press the Reset button on the front of the
controller. See Fig. 44. You have to do this within
30 seconds, or the verification will be cancelled.
To make it easy to reach the Reset button, open
the door on the front of the boiler and slide out the
control panel
before beginning the verification.
Fig. 44 - Reset Button on Controller
3. Don’t press the Reset button yet. We just want
to show you where the Reset button is located.
Change the parameter(s) you want to change.
4. When you are done entering parameters, the
next job is to do the verification. Login to the
system and press Begin.
Fig. 45 - Edit Safety Data
5. Once you are done changing safety
parameters, press Confirm. The system will
present a listing for each group of parameters
which includes a changed safety parameter.
See Fig. 46.
Fig. 46 - Safety Parameter Confirmation
6. For each group, check the list carefully. Press
Yes if all of the parameters in the group have
been entered correctly.
If you made changes in other safety-related
groups, verify the entries in those groups in
the same way. When the process is complete,
the system will tell you to reset the control
system.