Triggering or clearing alarm outputs manually – Interlogix DVR 41 User Manual User Manual
Page 110

10BChapter 11: Alarm settings
104
TruVision DVR 41 User Manual
To set up an alarm output:
1. Click the
Alarm Settings
icon in the menu toolbar and select
Alarm Output
.
2. Select the alarm output.
3. Select a timeout option.
The timeout setting lets you define how long a signal remains active after the
alarm has ended. If you select
Manually Clear
, the signal remains active until
it is manually acknowledged by pressing the alarm button on the front panel
or remote control (see “Triggering or clearing alarm outputs manually” below).
4. Select the recording schedules for the alarm output.
Click
Rule
and select the day of the week and the time periods during the day
when motion can be recorded. You can schedule up to eight time periods in a
day. Default is 24 hours.
Click
Apply
to save the settings. Click
Copy
to copy the settings to other
days of the week and holiday period.
Note: The time periods defined cannot overlap.
5. Click
OK
to return to the alarm output screen.
6. Click
Back
to return to live view.
Triggering or clearing alarm outputs
manually
When an alarm is activated, the DVR can be set up so that the alarm must be
manually acknowledged in order to be silenced. See “Setting up external alarms”
on page 102 for information on setting up an alarm to be manually cleared.
All user levels (administrator, manager and operator) can manually acknowledge
an alarm.
To trigger or clear alarm outputs manually:
1. Click the
Alarm settings
icon in the menu toolbar and select
Alarm Output
.
2. Click the
Manual Alarm
tab.
3. Select the desired alarm output and click one of the following buttons:
• Clear: Clear to stop alarm output.
• Trigger All: Trigger all alarm outputs at once. This action could be done,
for example, when you need to test them.
• Clear All: Stop all alarm outputs at once.
4. Click
Back
to return to live view. The alarm is silenced.
- Or -