6 relay output description, Relay output description – IC Realtime Specialty: 4-CH H.264E CUBE REAL-TIME DVR with BUILT-IN 5.6 LCD User Manual
Page 29
![background image](/manuals/678983/29/background.png)
29
6: Ctrl 12V(This is used for reset the senor)
485 A、B
485 communication port. They are used to control devices
such as PTZ.
+12(C)
This should input an external power input(Less than 1 A).
z
4-ch grounding alarm inputs. (Normal open or Normal close type)
z
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
z
Please parallel connect the Ground of the DVR and the ground of the alarm
detector.
z
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
z
If you need to reset the touched-off alarm remotely, you can use DVR to supply
controllable 12 V power to the alarm detector such as the smoke detector.
z
Use the same ground with that of DVR if you use external power to the alarm
device.
Figure 3-8
3.7.6 Relay Output Description
z
2 ways relay alarm output. Provide external power to external alarm device.
z
To avoid over loading, please read the following relay parameters sheet carefully.
(See below table)
z
The controllable +12v can be used to restore the smoke detector.
Please refer to Figure 3-9 for alarm input module information.
Figure 3-9
Please refer to Figure 3-10 for alarm output module information.