6: Ctrl 12V(This is used for reset the senor)

485 A、B

485 communication port. They are used to control devices
such as PTZ.

+12(C)

This should input an external power input(Less than 1 A).

z

4-ch grounding alarm inputs. (Normal open or Normal close type)

z

Please parallel connect COM end and GND end of the alarm detector (Provide

external power to the alarm detector).

z

Please parallel connect the Ground of the DVR and the ground of the alarm

detector.

z

Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)

z

If you need to reset the touched-off alarm remotely, you can use DVR to supply

controllable 12 V power to the alarm detector such as the smoke detector.

z

Use the same ground with that of DVR if you use external power to the alarm

device.

Figure 3-8

3.7.6 Relay Output Description
z

2 ways relay alarm output. Provide external power to external alarm device.

z

To avoid over loading, please read the following relay parameters sheet carefully.

(See below table)

z

The controllable +12v can be used to restore the smoke detector.

Please refer to Figure 3-9 for alarm input module information.

Figure 3-9

Please refer to Figure 3-10 for alarm output module information.