Figure 3-6

z

ALARMS1 in 1 to ALARM1 in 4 are corresponding to ALARM1 to ALARM4

respectively. The alarm gets activated in low voltage.

z

In ALARM1, 1-NO is normal open activation output. In ALARM2, 2-NO C

NC is a group of normal open/normal close activation output.

z

+12V is external alarm input. System needs external device to provide

+12V power and you can connect it to the alarm device power below 1A.

z

A/B is A cable and B cable to control 485 device. You can connect them to

devices such as decoder. Please parallel connect a 120Ω resistance if
there are too much PTZ decoders.

z

”:Ground cable.


You can refer to the following sheet and Figure 3-7 for MB(D)/AL series alarm
input and output information.












Figure 3-7

Parameter

Grounding Alarm

Ground Ground

line

Alarm in 1…4 1,

2,

…, 4. Become activated in low voltage,

Relay Output

1,2,3,4: NO and C(Normally Open and Com)
5: NO,C and NC(Normally Open, Com, Normally Closed)

Terminal