EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124

page 62 of 66

2 outputs (electromechanical

relays):

-

1 x 30 A res. output @

250 VAC SPST cycles

(K1)

for

compressor

management

-

1 x 8 A res. output @

250 VAC SPDT cycles

(K2) for defrosting or

evaporator

fan

management

5 outputs (electromechanical

relays):

-

1 x 30 A res. output @

250 VAC SPST cycles

(K1)

for

compressor

management

-

1 x 8 A res. output @

250 VAC SPDT cycles

(K2)

for

defrosting

management

-

2 x 8 A res. outputs @

250 VAC SPST cycles (K3

and K4) for management

of the evaporator fan

and the door resistances

of the of the condenser

fan

-

1 x 5 A res. output @

250 VAC SPST cycles

(K5) for management of

the cabinet light, needle

probe heating or UV light

The maximum current allowed on the loads is 16 A.

Type of actions and complementary

features:

1C

Communication port:

1 TTL serial port with MODBUS communication protocol