EVCO EVXV815P7 Installer manual User Manual
Page 44
EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 44 of 66
i5
0
1
- - - -
1
1
effect caused by the activation of the high
pressure input
0 = no effect
1 = the compressor and the evaporator fan
will be off and the condenser fan will
be on. On expiry of the time
established with parameter i7, the
display will show the flashing “HP”
code and the buzzer will be activated
(until the input is deactivated)
i6
0
1
- - - -
0
0
type of high pressure input 1
0 = normally open (input active with closed
contact)
1 = normally closed (input active with open
contact)
i7
-1
240
s
5
5
high pressure alarm signalling delay (“HP”
code)
-1 = the alarm will not be signalled
Par.
Min.
Max.
Unit
EVXV802
EVXV812
EVXV805
EVXV815
Digital outputs
u0
0
1
- - - -
1
not
present
utility managed by the output K2 (16)
0 = defrosting (in this case, the “d”
parameters will assume significance)
1 = evaporator fan (in this case, the “F”
parameters will assume significance)
u1
0
1
- - - -
not
present
0
utility managed by the output K4 (16)
0 = door
resistances
(in
this
case,
parameter u5 will assume significance)
1 = condenser fan (in this case, the P5,
F11 and F12 parameters will assume
significance)
u2
0
1
- - - -
not
present
0
enabling of cabinet light switch-on/off in
manual mode during "stand-by" status (17)
1 = yes
u5
-50.0
99.0
°C/°F (1)
not
present
20.0
cabinet temperature over which the door
resistances are off (4)