14 technical data, 1 technical data – EVCO EVXV815P7 Installer manual User Manual
Page 60
![background image](/manuals/675235/60/background.png)
EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 60 of 66
14
TECHNICAL DATA
14.1
Technical data
Purpose of the devices:
blast chiller controllers
Esecuzione:
open frame board
Dimensions:
EVXV802
EVXV812
EVXV805
EVXV815
63.8 x 110.0 x 45.8 mm (2.511
x 4.330 x 1.803 in; L x H x D).
63.8 x 110.0 x 50.3 mm (2,511
x 4.330 x 1.980 in; L x H x D).
Installation:
back panel via M3 studs
Protection rating:
IP00
Connections:
6.3 mm faston (0.248 in, power supply and outputs), screw
terminal board (inputs), 6 pole connector (serial port).
Temperature of use:
from 0 to 55 °C (from 32 to 131 °F)
Storage temperature:
from -25 to 60 °C (from -13 to 140 °F)
Humidity for use:
from 10% to 90% relative humidity without condensate
Pollution situation:
2
Power supply:
EVXV802
EVXV812
EVXV805
EVXV815
230 VAC (±10%), 50/60 Hz,
2.3 VA max. or 115 VAC
(±10%), 50/60 Hz, 5 VA max.
230 VAC (±10%), 50/60 Hz,
2.8 VA max. or 115 VAC
(±10%), 50/60 Hz, 5 VA max.
Overvoltage category:
III
Clock:
EVXV802
EVXV812
EVXV805
EVXV815
not available.
incorporated
(with
condenser)
not available.
incorporated
(with
condenser)
Battery autonomy in the event of a power-cut: 24 h with battery
fully charged
Battery charging time: 2 min (the battery is charged by the device
power supply)