EVCO EVXV815P7 Installer manual User Manual
Page 45
EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 45 of 66
u6
1
240
min
not
present
5
if parameter u11 is set at 1, maximum
duration of needle probe heating; see also
parameter u7
if parameter u11 is set at 2, duration of UV
light switch-on for the sterilisation cycle
u7
-50.0
99.0
°C/°F (1)
not
present
40.0
needle
probe
heating
end
temperature
(temperature detected by the needle probe);
also see parameter u6
u11
0
2
- - - -
not
present
0
utility managed by the output K5 (16)
0 = cabinet
light
(in
this
case,
the
AUXILIARY key and parameters i0 and
u2 will assume significance)
1 = needle probe heating (in this case, the
AUXILIARY key and parameters u6 and
u7 will assume significance)
2 = UV light (in this case, the AUXILIARY
key and parameter u6 will assume
significance)
Par.
Min.
Max.
Unit
EVXV802
EVXV812
EVXV805
EVXV815
Serial communication (MODBUS)
LA
1
247
- - - -
247
247
device address
Lb
0
3
- - - -
2
2
baud rate
0 = 2,400 baud
1 = 4,800 baud
2 = 9,600 baud
3 = 19,200 baud
LP
0
2
- - - -
2
2
Parity
0 = none
1 = odd
2 = even
Notes:
(1)
the unit of measurement depends on parameter P2
(2)
appropriately set the parameters relative to the regulators after modification of parameter P2
(3)
the time established with the parameter is counted also during the "on" status and during the "stand-by" status
(4)
the parameter differential is 2 °C/4 °F
(5)
on device switch-on (or cycle start), if the condenser temperature is already over that established with
parameter C7, parameter C8 will have no effect
(6)
defrosting is only enabled during storage, except for defrosting on blast chilling start and deep freezing start,
which can be established using parameter d4