the device memorises the defrosting interval count every 30 minutes; the modification of parameter d0 has
effect from the conclusion of the previous defrosting interval (or the activation of defrosting in manual mode)
(8)
if on activation of defrosting, the previous compressor switched on at a time shorter than that established with
parameter d15, the compressor will remain on longer for the fraction of time necessary to complete this time
period
(9)
the temperature alarms are only enabled during storage
(10)
during defrosting, pre-dripping, dripping and evaporator fan standstill, the temperature alarms are not enabled,
on condition that they occurred after activation of defrosting. When the door is open, i.e. if the door micro
switch input is active and the parameter i0 is set at values different to 0, the maximum temperature alarm is
not enabled, on condition that it occurred after the door was opened
(11)
if parameter P4 is set at 0, during pre-cooling, blast chilling and deep freezing the evaporator fan will be on and
during storing the device will operate as if parameter F2 it were set at 2
(12)
the condenser fan is off when the compressor is off, on expiry of the time established with parameter F12
(13)
if parameter P5 is set at 0, the condenser fan will function parallel to the compressor
(14)
the door open is enabled only using the "run" state
(15)
if the door is opened during defrosting or evaporator fan standstill, opening has no effect on the compressor
(16)
modify the parameter during the "stand-by" status to prevent damage to the utility
(17)
if parameter u2 is set at 0, device switch-off will cause the cabinet light to switch off and on successive switch
on the cabinet light will remain off. If parameter u2 is set at 1, device switch-off will not cause the cabinet light
to switch off and on successive switch-on the cabinet light stays on.