EVCO EVXV815P7 Installer manual User Manual
Page 43
EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 43 of 66
F17
-50.0
99.0
°C/°F (1)
90.0
90.0
cabinet
temperature
above
which
the
evaporator fan is off during pre-cooling, blast
chilling and deep freezing (only if parameter
F0 is set at 1 or 2); also see parameter F8
Par.
Min.
Max.
Unit
EVXV802
EVXV812
EVXV805
EVXV815
Digital inputs
i0
0
2
- - - -
2
2
effect caused by opening the door, i.e. by
activation of the door micro switch (14)
0 = no effect
1 = the compressor and the evaporator fan
will be off and the cabinet light will be
on. On expiry of the time established
with parameter i2, the display will
show the flashing “id” code and the
buzzer will be activated (until the door
is closed); also see parameter F15
(15)
2 = the evaporator fan will be off and the
cabinet light will be on. On expiry of
the time established with parameter
i2, the display will show the flashing
“id” code and the buzzer will be
activated (until the door is closed);
also see parameter F15
i1
0
1
- - - -
0
0
type of door micro switch input contact
0 = normally open (input active with closed
contact)
1 = normally closed (input active with open
contact)
i2
-1
120
min
5
5
door open alarm signalling delay (“id” code) ;
on expiry of the time established with the
parameter, the compressor will be off
-1 = the alarm will not be signalled