Comtrol ES7528 User Manual
Page 164
164 - Power over Ethernet (CLI)
RocketLinx ES7528 User Guide: 2000509 Rev. C
Configuration Using the Command Line Interface (CLI)
PoE Budget Warning (%)
Set
Switch> enable
Switch# config term
Switch(config)# interface fa1
Switch(config-if)# poe budget warning
<0-100> 0 is disable, valid range is 1 to 100 percentage
Switch(config-if)# poe budget warning 60
PoE Priority
Set
Switch> enable
Switch# config term
Switch(config)# interface fa1
Switch(config-if)# poe priority
critical Hightest priority level
high High priority level
low Low priority level
Switch(config-if)# poe priority critical
PoE Schedule Weekday Hour
Enable Hour 1, 3, 5
and 10 to 23 on
Sunday
Switch> enable
Switch# config term
Switch(config)# interface fa1
Switch(config-if)# poe schedule
<0-6> Weekday: valid range 0-6 (0=Sun, 1=Mon..., 6=Sat)
Switch(config-if)# poe schedule 0 1,3,5,10-23
Disable Sunday
Schedule
Switch(config-if)# no poe schedule 0
PoE Budget DC1/DC2
Set
Switch(config)# poe
disable Disables power over ethernet
enable Enables power over ethernet
budget Configure the power budget of power over ethernet
pd-detect Configure PD status detection
Switch(config)# poe budget
DC1 Power source : DC 1
DC2 Power source : DC 2
vin Input voltage
warning Warning water level
Switch(config)# poe budget DC1
[POWER] System budget : 1 - 400 Watts
Switch(config)# poe budget DC1
DC1 Power source : DC 1
DC2 Power source : DC 2
vin Input voltage
warning Warning water level
Switch(config)# poe budget DC1 400