Syslog configuration – Comtrol ES7506 User Manual
Page 84

84 - SysLog Configuration
RocketLinx ES7506 User Guide: 2000529 Rev. F
Configuration Using the Web Interface
SysLog Configuration
The System Log provides the system administrator ES7506 events history. There are two System Log modes
provided by the ES7506, Local mode and Remote mode.
When enabling Local or Both modes, you can monitor the system logs in the Monitor and Diag /Event Log
page.
Port Event
Warning is sent when…..
Link-Up
The port is connected to another device.
Link-Down
The port is disconnected. For example, the cable is pulled out or the opposing
devices is down.
Both
The link status changed.
PoE Powering Event
Warning is sent when…..
Enable
The PoE port is powering.
PoE Powering Event
Warning Event is sent when…..
Disable
The PoE port is not powering.
Apply
Click Apply to apply the settings.
Note: You must Save the settings (
), if you want to maintain these
settings if the ES7506 is powered off.
Warning - SysLog Configuration Page
Syslog Mode
There are two system logs available:
•
Local Mode: The ES7506 prints the events that have been
selected in the Event Selection page to the System Log table of
the ES7506. You can monitor the system logs in the Monitor
and Diag /Event Log page.
•
Remote Mode: Assign the IP address of the System Log server.
The ES7506 sends the events that occurred in the selected in
Event Selection page to System Log server that you assign.
•
Both: This enables both Local and Remote modes.
Remote IP Address
The IP address of the System log server.
Apply
Click Apply to apply the settings.
Note: You must Save the settings (
), if you want to
maintain these settings if the ES7506 is powered off.