136 - Warnings (CLI)

RocketLinx ES7506 User Guide: 2000529 Rev. F

Configuration Using the Command Line Interface (CLI)

Warnings (CLI)

The ES7506 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log and SMTP Email Alert.

Optionally, you can use the web user interface for configuration, see

Warning

on Page 81.

This table provides detailed information about the command lines of the warning configuration.

Fault Relay Output

Dry Output

Switch(config)# relay 1 dry
<0-4294967295> turn on period in second
Switch(config)# relay 1 dry 5
<0-4294967295> turn off period in second
Switch(config)# relay 1 dry 5 5

Ping Failure

Switch(config)# relay 1 ping 192.168.250.33

reset reset a device
Switch(config)# relay 1 ping 192.168.250.33 reset
<1-65535> reset time
Switch(config)# relay 1 ping 192.168.250.33 reset 60
<0-65535> hold time to retry
Switch(config)# relay 1 ping 192.168.250.33 reset 60 60

Port Link Failure

Switch(config)# relay 1 port
PORTLIST port list
Switch(config)# relay 1 port fa1-5

Power Failure

Switch(config)# relay 1 power
<1-2> power id
Switch(config)# relay 1 power 1
Switch(config)# relay 1 power 2

Super Ring Failure

Switch(config)# relay 1 ring

Disable Relay

Switch(config)# no relay
<1-2> relay id
Switch(config)# no relay 1 (Relay_ID: 1 or 2)

Display

Switch# show relay 1
Relay Output Type : Port Link
Port : 1, 2, 3, 4
Switch# show relay 2
Relay Output Type : Super Ring