Thermostat wiring – Braeburn 140404 User Manual
Page 7

3 HEAT / 2 COOL
R
24 VAC Power
 W1 Heat Call Stage 1
 W2 Heat Call Stage 2
 
W3 Heat Call Stage 3
 Y1 Cooling Call Stage 1
 Y2 Cooling Call Stage 2
 G 
Fan Call
C 24 VAC Transformer Common
1 HEAT / 1 COOL - No Auxiliary Heat
R
24 VAC Power
 O/B Changeover Valve [Note 2]
 Y1 Compressor Call (1st Stage Heating/Cooling)
 G 
Fan Call
C
24 VAC Transformer Common
[Note 1]
2 HEAT / 2 COOL - No Auxiliary Heat
R
24 VAC Power
O/B Changeover Valve [Note 2]
L
Optional System Fault Monitor
 Y1 Compressor Call Stage 1 (1st Stage Heating/Cooling)
 Y2 Compressor Call Stage 2 (2nd Stage Heating/Cooling)
 G 
Fan Call
C
24 VAC Transformer Common
[Note 1]
HEAT PUMP THERMOSTATS (for use on heat pump systems only)
2 HEAT / 1 COOL - With Auxiliary Heat
R
24 VAC Power
O/B Changeover Valve [Note 2]
L
Optional System Fault Monitor
 W2 Auxiliary Heat Relay (2nd Stage Heating)
 Y1 Compressor Call (1st Stage Heating/Cooling)
 E 
Emergency Heat Call
G
Fan Call
C
24 VAC Transformer Common
[Note 1]
3 HEAT / 2 COOL - With Auxiliary Heat
R
24 VAC Power
O/B Changeover Valve [Note 2]
L
Optional System Fault Monitor
 AX1 Auxiliary Heat Relay (3rd Stage Heating)
 Y1 Compressor Call (1st Stage Heating/Cooling)
 Y2 Compressor Call (2nd Stage Heating/Cooling)
 
E
Emergency Heat Call
G
Fan Call
C
24 VAC Transformer Common
[Note 1]
4 HEAT / 2 COOL - With Auxiliary Heat
R
24 VAC Power
O/B Changeover Valve [Note 2]
L
Optional System Fault Monitor
 AX1 Auxiliary Heat Relay (3rd Stage Heating)
 AX2 Auxiliary Heat Relay (4th Stage Heating)
 
Y1 Compressor Call (1st Stage Heating/Cooling)
 Y2 Compressor Call (2nd Stage Heating/Cooling)
 
E
Emergency Heat Call
G
Fan Call
C
24 VAC Transformer Common
[Note 1]
NOTES
[1] Wiring to the C terminal is required only for thermostat power.
[2] O (Cool active) or B (Heat active) must match the zone panel 
 
installer settings.
Thermostat Wiring
3.2
7