beautypg.com

Braeburn 2200 User Manual

Warning, Builder series, Programmable thermostats

background image

WARNING

Important Safety Information

1

Replacing Existing Thermostat

Builder Series

Programmable Thermostats

Single Stage Heat / Cool

Conventional and Heat Pump

Multi-Stage 2 Heat / 1 Cool

Conventional and Heat Pump

• Always turn off power to the air conditioning or heating system prior to

installing, removing, cleaning or servicing thermostat.
• This thermostat requires either 24 Volts AC Power or two (2) properly installed
“AA” alkaline batteries for normal operation and control of the heating or

cooling system. Refer to “Low Battery Detection and Replacement” section for
more information.
• This thermostat also requires two (2) properly installed “AA” alkaline batteries
to retain clock setting in the event of loss of AC Power due to a power outage
or rolling blackouts when used as a hardwired thermostat.
• This thermostat should only be used as described in this manual. Any other
use is not recommended and will void the warranty.

Specifications
Installation
Testing Your New Thermostat
Programming User Settings
Setting Your Energy

Saving Program

Temperature Adjustment
Additional Operation

Features
Battery Replacement
Troubleshooting
Wiring Diagrams

1
2
3
4
5

6
7

8
9

10

1

Specifications

• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals) (Model 2000, 2000NC)
3 amp total maximum load (all terminals) (Model 2200, 2200NC)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)

• Model 2000, 2000NC: Compatibility with low voltage single stage gas, oil or
electric heating or cooling systems, including single stage heat pumps; can
also be used on 250mv to 750mv millivolt heating only systems.
• Model 2200, 2200NC: Compatibility with low voltage multi-stage gas, oil or
electric heating or cooling systems, including multi-stage heat pumps.
• Model 2000, 2000NC Terminations: Rc, Rh, B, O, Y, W, G, C
• Model 2200, 2200NC Terminations: R, O, B, C, Y1, E/W1, G, W2

1

Specifications

cont.

Installation

2

Before Installing, Programming or Operating,

PLEASE READ ALL INSTRUCTIONS

Old Terminal from

Existing Thermostat

New Terminal for

New Thermostat

(2000, 2000NC)

New Terminal for

New Thermostat

(2200, 2200NC)

Terminal

Description

V or Rc

Rc

Cooling

Transformer

M, 4, Rh, or R

Rh

Heating

Transformer

R, V-VR or VR-R

R

24 VAC

B

B

B

Reversing Valve

(Heating)

O

O

O

Reversing Valve

(Cooling)

Y, Y1 or M

Y

Y1

Cooling or

Compressor for

HP System

E, H, W, W1 or 4

W

E/W1

1st Stage Heat

or Emergency Heat

G or F

G

G

Fan Control

C, X or B

C

C

24 VAC Common

W1, W2 or W-U

W2

2nd Stage Heat

2000

2000NC

2200

2200NC

Most thermostats have three parts:

• The cover, which may snap or hinge over the existing thermostat.
• The electronics or body, which controls the existing system.
• The sub-base, where the wires attach through the wall to the existing system.
1. Always turn off power to the air conditioning or heating system prior to

removing existing thermostat.
2. Carefully remove the cover and electronics body from the old thermostat sub-base.
Depending on the brand, these parts may pull off or need to be unscrewed. The
old sub-base should remain wired and on the wall until steps 4 and 5.
3. Label every old wire with the letter of the connection to which the wire is

attached. Example letters are R, M, Y etc. Depending on the brand of the old

thermostat, your letters may be different.
4. After labeling the old wires, loosen each connection and remove them from old
sub-base. Secure the wires to prevent them from slipping into the hole in the wall.
5. Remove the old sub-base from the wall, again being careful that the wires do
not slip into the hole in the wall.
6. Use the chart below to determine the new thermostat connections. As an

example, if the old thermostat had a G connection, it goes to G on the new

thermostat. Note the chart includes information for Braeburn

®

2000, 2000NC,

2200 and 2200NC thermostats. Be sure to use the correct column for the
new thermostat.

This manual is related to the following products: