Braeburn 1220NC User Manual
Detailed installer guide, 1020nc, 1220nc
This thermostat requires 24 Volt AC Power or two (2) properly installed
“AA” Alkaline batteries for proper operation. When connecting 24 Volt
AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use
will void warranty.
1020NC
Single Stage Heat / Cool
Conventional and Heat Pump
1
Specifications
2 About Your Thermostat
3 Installation
4 System Testing
5 Setting User Options
6 Operating Your Thermostat
7 Additional Operation Features
8 Thermostat Maintenance
®
Warning
Turn off power to the heating or cooling
equipment before installation.
Attention
For installation by experienced service
technicians only.
1220NC
Up to 2 Heat / 1 Cool
Conventional and Heat Pump
Read all instructions before proceeding.
This thermostat is compatible with:
• Single stage heat / cool conventional and heat pump systems
• Conventional systems up to 2 heat / 1 cool (1220NC only)
• Single compressor heat pump systems with an auxiliary heat stage (1220NC only)
• 250 – 750 millivolt heat only systems
Electrical and control specifications:
• Electrical Rating: 24 Volt AC
• 1 amp maximum load per terminal
• AC Power: 18 – 30 Volts AC
• DC Power: 3.0 Volt DC (2 “AA” Alkaline Batteries Included)
• Control Range: 45° – 90° F (7° – 32° C)
• Temperature Accuracy: +/- 1° F (+/- .5° C)
Terminations
• 1020NC – Rc, Rh, O, B, Y1, W1, G, C
• 1220NC – Rc, Rh, O, B, Y1, E/W1, G, W2, C
1 Specifications
1020NCW-100-03
Non-Programmable
Thermostats
Model number is located on back of thermostat
Detailed