beautypg.com

Braeburn 140404 User Manual

Page 15

background image

LED

COLOR

INDICATION

Thermostat LED’s (4 Positions)

R

Red

24 VAC available to Thermostat

Y1

Yellow

Thermostat First Stage Compressor Call

Y2

Yellow

Thermostat Second Stage Compressor Call

W1/E/AX1

White

Thermostat Call for W1 or E or AX1

W2/AX2

White

Thermostat Call for W2 or AX2

O/B/W3

Yellow

Thermostat Call for O, B or W3

G

Green

Thermostat Fan Call

Damper LED’s (4 Positions)

Power Close / Power Open

Red / Green

Red On Damper Closed; Green on Damper Open

No light when wiring short detected

Fire Alarm LED

Fire Indication

Red

Fire Terminals Active - Panel is Shut Down

15

In addition to LED’s, the expandable zone panel has a full function built-in backlit display panel that provides
information on the current operations of the zone panel. When the expandable zone panel is running in normal
operation, the display is updated continuously to show the system operating parameters. The system will show
the following status screens on the display.

Number of Heat Calls currently being serviced. Check the panel
LED if it is necessary to determine exactly which zones are calling
for heat operation. If Auxiliary Heat or Emergency Heat calls are
active, the display will replace heat calls with Auxiliary or
Emergency Heat Calls.

Number of Cool Calls currently being serviced. Check the panel
LED if it is necessary to determine exactly which zones are calling
for cooling operation.