Fan Stage(s) Test ON or OFF
This test turns on all fan stages and commands all dampers
to open. Press

SELECT to test or NEXT to advance to the next test.

Operation

6

The Expandable Zone Panel has LED’s and a built-in display
to tell the installer and the system owner the current operating
mode of the panel. Refer to the figure below and the following
descriptions of the panel LED’s for operation information.

Damper Control Test PO or PC
This test powers all dampers open or closed. Press

SELECT to test

or

NEXT to advance to return to first test.

LED

COLOR

INDICATION

Panel Status LED

Panel Power

Green

Flashing Green When Normal

Equipment LED’s

Rh

Red

24 VAC at equipment Rh Terminal

Rc

Red

24 VAC at equipment Rc Terminal

Y1

Yellow

First Stage Compressor Call Active

Y2

Yellow

Second Stage Compressor Call Active

G

Green

First Stage Fan Call Active

G2

Green

Second Stage Fan Call Active

W1/E/AX1

White

W1 or E or AX1 Call Active

W2/AX2

White

W2 or AX2 Call Active

O/B/W3

Green

Reversing Valve Active or W3

L

Yellow

Input from Equipment Check is Active

14