ALTANA Micro-Wave-Scan Manual User Manual
Page 21

20
Getting started
After completing a measurement, the
measurement results are displayed. Performing
the measurement requires some practice. The
following error messages are especially likely to
occur during the first trials.
A warning signal is heard and the light diode
flashes at a rapid rate. At the same time, a
message appears in the display indicating the type
of error:
Speed
You have moved the measurement unit too
quickly or unevenly over the sample. Confirm this
information by pressing the operate button and
repeat the measurement.
Scan length
The required scan length has not been reached
completely.
Repeat the measurement, moving the device until
a short audio confirmation is heard.
Small areas can be measured by moving the
instrument back and forth.
Acceleration
The instrument was accelerated too fast across the
specimen or the scan direction was changed too
fast.
Confirm the message by pressing “operate” and
repeat the measurement.
Scan length
Error
OK
Acceleration
Error
OK
Speed
Error
OK
SAMPLE 01
n = 1/1
du
8.1
Wd
7.8
Wa 10.8
SW
15.7
Wb 17.4
LW
7.3
Wc
8.7