Page 6

background image

English

ENGLISH

Installation

• The SL-C must be installed only after securing the minimum safety distance between the SL-C and the

hazardous zone or hazard as established by the applicable regulations of the country or region in which
the SL-C is being used.

• Choose locations for the installation of SL-C transmitters and receivers so that they are not subject to

the effects of light reflected from glossy surfaces in the area.

• Use the same models (same beam axis) for transmitter/receiver pairs.
• The SL-C must be installed in such a way that machine operators cannot reach the hazardous zones or

hazards of the machine without passing through the SL-C's detection zone. Strictly avoid installations
which allow machine operators to access the area between the SL-C and the machine, or where ma-
chine operators can approach the machine's hazardous zones, without passing through the SL-C's
detection zone.

• Always perform tests after installing the SL-C in accordance with the test procedures established in this

instruction manual, verifying that the test pieces are detected in all of the detection zones.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the fixed blanking function, additional

safety measures must be implemented for the zone in which that function is enabled so that it is impos-
sible to reach the hazardous zone or hazards of the machine by passing through that zone. This func-
tion cannot be used with SL-C**L having the detection capability of 45 mm diameter.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the floating blanking function, the

minimum safety distance will be affected due to the fact that the function has a negative effect on the
detection capability. Therefore, in such cases, calculate the minimum safety distance using the new
value for detection capability with the floating blanking function enabled and apply the result for the SL-
C installation. This function cannot be used with SL-C**L having the detection capability of 45 mm
diameter.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the floating blanking function, confirm

that the actual number of beam axes with which the floating blanking function is active matches the
number of beam axes specified in the floating blanking function setting. This function cannot be used
with SL-C**L having the detection capability of 45 mm diameter.

• When the Blanking Blind Protection Unit (SL-C08SB/SL-C16SB) is used to install the SL-C, a test must

be carried out according to the procedures described in this instruction manual to confirm that the test
piece can be detected in all detection zones including the detection zone that can be detected by the
Blanking Blind Protection Unit. This function cannot be used with SL-C**L having the detection capabil-
ity of 45 mm diameter.

• Securely tighten mounting brackets and cord (cable) connectors used in the installation of the SL-C in

accordance with the torque values established in this instruction manual.

4. Circuit Design and Wiring

Always turn off the device power when performing electrical wiring.

Follow electrical standards and regulations for the country or region in which the SL-C is being used when
performing the electrical wiring. Only qualified persons should perform wiring.

Do not place any cables or electrical lines used in wiring the SL-C in the same duct as high-voltage
electrical or power lines or in parallel with such lines.

Do not extend transmitter and receiver cables over a maximum distance of 30 meters (98.43 ft.).

Install the mechanism used to reset the interlock (switches, etc.) in a position from which the condition of
the entire hazardous zone can be checked. Do not install the reset mechanism in a position where it can
be operated within the hazardous zone.

The control outputs (OSSD for SL-C Series or FSD for SL-R11) of the two systems provided in the SL-C
must both be used to build a safety system. Building a safety system with just one of these systems
cannot stop the machine due to a control output malfunction and can result in a serious accident, includ-
ing serious injury or death to the machine operator.

5. Testing and Maintenance

Always perform testing in accordance with the test procedures after maintenance, adjustment, or calibra-
tion of the target machine or the SL-C, and before the machine start-up.

If the SL-C does not operate properly when tested in accordance with the test procedures established in
this instruction manual, do not operate the machine.

Periodically examine the machine to verify that all brakes, other stop mechanisms, and control devices
operate reliably and accurately in addition to checking the SL-C.

The responsible personnel must perform maintenance procedures as established in this instruction
manual at least once every six months to ensure safe device operation.

v