3-4 For SL-PC Cable (main unit plug - M12 connector)

8

5

6

7

1

2

3

4

Main unit
connector

2. Cable

3. M12 connector

3. M12 connector

1. Cable length

Transmitter

Main/sub select input

+24 V

Test input

Light interference prevention input (+)

RS-485 (A)
RS-485 (B)

0 V

Light interference prevention input (–)

Receiver

OSSD2

+24 V

OSSD1

Light interference prevention output (+)

RS-485 (A)
RS-485 (B)

0 V

Light interference prevention output (–)

Terminal No.

of connector

1
2
3
4
5
6
7
8

1. Cable length

SL-PC5P 5m (16.4 ft.)
SL-PC5N 5m (16.4 ft.) (Cannot be used for establishing a connection with the SL-R11(E).)
SL-PC10P 10m (32.81 ft.)

2.

Cable color
Transmitter: gray
Receiver: black

3.

M12 connector

WARNING

Limit the length of transmitter and receiver cables to 30 meters (1181.1") or less. If the cable
length exceeds the limit, the SL-C may not operate normally and a serious accident, such as
an injury or death of a machine operator, may result. In addition, when bent or flexed, these
cables should be allowed a minimum bend radius of 5 mm (0.2").

3-5 Series Connection

2 or more sets of the SL-C can be connected by using a pair of dedicated series connection cables to form a light
curtain with a single set of output logic.
If any beam axis of any series-connected SL-C unit is blocked, the OSSD output (or FSD output) is turned OFF and
the machine can be stopped.
This function is valid only when the number of SL-C connected in series is 4 pairs or less and the total number of SL-
C beam axes is 192 or less. The response time of the SL-C Series is not affected by the series connection.
Use the series connection cables.
• SL-S0: Cable length 0.08 m (3.15")
• SL-S1: Cable length 0.15 m (5.91")
• SL-S2: Cable length 0.5 m (1.64 ft.)
• SL-S3: Cable length 3 m (9.84 ft.)
• SL-S4: Cable length 1 m (3.28 ft.)
• SL-S10: Cable length 10 m (32.79 ft.)
When installing a series connecStion cable, remove the top edge connector cover, and then install the cable.

WARNING

Use only the series connection cables provided by KEYENCE (

See 1-2-2 “Cables” (

page 1-3) for special cable types and relevant information). Otherwise, the SL-C may
not operate normally and serious harm, such as an injury or death of the machine
operator, may result. Synchronization cables must be shielded cables. Failure to use
shielded cable may result in significant harm the machine operator, including serious
injury or death. When connecting the SL-C units in a series configuration by using the
SL-S10, limit the number of the SL-S10 units to two or less, and the total length of the
cables including the series-connection cables to 43 m (141.08 ft.) or less.

Connection cable for transmitter
(gray)

Connection cable for receiver
(black)

Tr

ansmitter

Receiv

er

Tr

ansmitter

Receiv

er

Synchronization cable

(Orange)

(Orange/black)

Output

Unit 2

Unit 1

For connections of the transmitter and receiver of Unit 1,

refer to 3-3 “When Only

the SL-C is Used” (

➮ page 3-3) .