beautypg.com

English – KEYENCE SL-C Series User Manual

Page 38

background image

Chapter 3 Wiring

3-2

3

English

ENGLISH

2. Recommended Dedicated Power Supply Unit
The SL-U2 is offered as the SL-C dedicated power supply. The SL-U2 is a power supply that com-
pletely satisfies the above requirements.

Standard No.
EN60950

Safety EN50178
standard

UL60950 (R/C)
UL508 (Listing)
EN55011 Class A

EMC standard

EN61000-6-2
FCC Part 15B Class A

24V DC

100 to

240 V AC

+

Ð

PE(GND)*

SL-U2

SL-U2

OC

+

-

N

L

CAUTION

100-240V

AC

ONL

Y

(*)The PE terminal is a protective conductor terminal that must be connected to a protective earthing

conductor in the building.

System

Switching Power Supply

Input power supply voltage

AC 100 to 240 V

±10% (50/60 Hz)

Overvoltage category

Output voltage

DC 24 V

±10%, Class 2

II

Ripple/noise

240 mVp-p or less

Output capacity

1.8 A

Ambient temperature

-10

°C to +55 °C (non-condensing)

Relative humidity

35% to +85% RH (non-condensing)

Pollution degree

2

Withstand voltage

AC 1,500 V, 1 min. (between all external terminals and case)

Vibration resistance

Shock resistance

10 to 55 Hz, 0.7 mm (0.03") compound amplitude, 20 sweeps each in X, Y, and Z directions

100 m/s

2

, 1,000 iterations each in X, Y, and Z directions

Insulation resistance

At least 50 MW (DC 500 V mega, between all external terminals and case)

Supply voltage interruption

10 ms or less

Power consumption

135VA

Weight (excluding dedicated brackets) Approx. 240 g

Model

SL-U2

Environ-
ment

WARNING

Always use a power supply that can fully satisfy the above requirements or use the
recommended SL-U2 power supply. Otherwise, the UL61496-1 requirements may
not be satisfied and the SL-C may not be recognized as a safety component.