beautypg.com

English – KEYENCE SL-C Series User Manual

Page 14

background image

Chapter 1 Overview and Specifications

1-6

1

English

ENGLISH

Common specifications

Environ-
mental
specifica-
tions

Material

Approved
standards

SL-C**F Operating distance
SL-C**H/SL-C**L Operating distance
Effective Aperture Angle
Response time
Light source
Operation form
Rating

Power voltage
Output type
Max. load current
OFF-state voltage

Protective structure
Ambient temperature
Storage ambient temperature
Relative humidity
Storage ambient humidity

Vibration
Shock
Main unit case
Upper case/Lower case
Overlay

EMC

EMS
EMI

Safety

OSSD
Output

Model

IP65 (IEC60529)

-10

°C to 55°C (No frost)

-10

°C to 60°C (No frost)

35 % to 85 %RH (No condensation)

35 % to 95 %

Ambient light

White incandescent lamp: 5,000

rx or less Sunlight: 20,000rx or less

10 to 55 Hz, 0.7 mm compound amplitude, 20 sweeps each in X, Y, and Z directions

100 m/s

2

(Approx. 10G) 16ms pulse, in X, Y, Z directions 1,000 times each axis

Aluminum

Zinc die-cast

Polycarbonate

UL61496-1

FCC Part15 Class A

UL61496-1 (

type

4 ESPE)

UL61496-2 (

type

4 AOPD)

UL508

0.1 to 7 m
0.3 to 9 m

Max.

±2.5° (When operating distance is 3 m (9.84 ft.) or more)

15 ms*

1

Infrared LED (850 nm)

Turns on when light is received from all light beams (except when the blanking function is used)

24V DC

±10% (Ripple P-P 10% or less)

2 outputs each for PNP and NPN, Can be changed using the connector cable

300 mA*

2

2.5 V (with a cable length of 7 m (22.97 ft.))

Max. 100

µA*

3

0.47

µF (with a load resistance of 100 Ω)

Max. 2.5

Ω*

4

SL-C Series

0

100

200

300

(mA)

10

20

30

40

50

(

°C)

Leakage current

Max. capacitive load
Load wiring resistance

*1 OFF

➝ ON return time is 125 ms.

*2 Note the derating illustrated in the graph to the right when using PNP output.
*3 Includes when the SL-C Series power supply is OFF or when there is a disconnection in the power

supply line.

*4 In order to guarantee the proper operation of the SL-C safety circuit, the wiring resistance (excluding

dedicated cable wiring resistance) of the cabling connected to the hardware to which the OSSD output
and OSSD input are connected must be 2.5

Ω or less. For NPN output type cable, do not let wiring

resistance exceed a maximum of 1.0

Ω when the cable length is 15 m (49.21 ft.) or greater and the

load current is 200 mA or higher.