Setting conditions – KEYENCE LS-Navigator User Manual
Page 12

1
LS-Navigator-M-NO1-E
1-4
1-1 LS-Navigator Overview
The measured values that are received from the controller can be transferred to an Excel sheet with the
specifications from the specified logging method
Logging methods
1. Click logging
: Transfers the measurement values when the button is clicked.
2. Timer logging
: Transfers the measurement values at specified intervals.
3. External
trigger
logging: Transfers the measurement values when the controller communication setting is
[Printer Mode] and a trigger (timing input) is entered from the controller.
Operations that use LS-Navigator require certain setting conditions.
Set the following conditions before using the software.
1. Switch the controller to [Measurement] mode when communicating between the computer and the controller.
2. The connected model selected on the LS-Navigator (computer) must be the same as the controller model (LS-
7600/LS-7500/LS-7000 series).
3. The connected model selected on the LS-Navigator (computer) must be the same as the controller model (LS-
7600/LS-7500/LS-7000 series).
4. The settings for [Units] ([D-UNIT]) and [Minimum display unit] ([D-RES]) must be the same for the LS-
Navigator (computer) and the controller (LS-7600/LS-7500/LS-7000 series).
5. [PANEL] must be set for [P-SELECT] in the environment settings for the controller.
[NORMAL] must be set for [D-MODE].
6. When [TERMINAL] is set for [P-SELECT] in the environmental settings for the controller, the selected
program number cannot be sent or read. Also, backup and restore functions cannot be executed for all of the
settings.
Function for transferring measurement values to an Excel sheet
Setting conditions
Example of transfer to an Excel sheet
Note
When [Ext trig logging] is selected as the method for transferring the measurement value to the Excel sheet, select
[PRINTER1] or [PRINTER2] for [D-MODE].