Rs-232/422 baud rates, Rs‑232/422 baud rates, Control master dip switch – Aviom 6416dio User Manual
Page 83: Digital i/o module

73
v
irtuAl
d
AtA
c
Ables
RS-232/422 Baud Rates
To set a baud rate, determine the appropriate baud rate for data transfer
by referring to the external send/receive devices’ documentation. Set both
devices to communicate using the same baud rate. Finally, set the Pro64
devices to the same baud rate and activate the VDCs using the front‑panel
interface.
75Ω
TERMINATION
B
A
Digital I/O Module
AES3 I/O CHANNELS 9–16
AES3 I/O CHANNELS 1–8
6416
dio
AC POWER
1 AMP
PIN 1 = GND
PIN 4 = 24VDC
IN
OUT
RS-232/422
FUSE: 250VAC-F4AL
BACKUP POWER
1 2 3 4
1
2
3
4
GPIO INPUT
UP = ISOLATED
DN = TTL
PORT SETUP
1–8
CTRL MASTER
232 / 422
10
12
RESERVED
9, 11
ON
WORD CLOCK
IN
75Ω
TERMINATION
OUT
DIGIDESIGN / TASCAM COMPATIBLE
YAMAHA COMPATIBLE
VIRTUAL DATA CABLE PORTS
Here, the 6416dio is set for a 57,600 baud RS-232 transfer with 8 data bits, no
parity, and stop bit set to 1. (Black indicates the switch handle.)
The following table lists the DIP switch settings for the available RS‑232/422
baud rates.
Switch
Baud Rate
1
2
3
4
1200
off
off
off
off
2400
off
off
off
on
4800
off
off
on
off
7200
off
off
on
on
9600
off
on
off
off
14400
off
on
off
on
19200
off
on
on
off
28800
off
on
on
on
38400
on
off
off
off
57600
on
off
off
on
31250 (MIDI)
on
off
on
off
Control Master DIP Switch
In the RS‑232/422 DIP switch block on the 6416dio, switch #10 is used to
set the module as the network’s Control Master. Only one module can be
designated as Control Master in a Pro64 network.