Bank select – Aviom 6416dio User Manual
Page 48

38
F
roNt
P
ANel
F
eAtures
Press the inc/dec (up/down) buttons to change the A-Net Slot range in the
Input or Output section of the interface.
On a sixteen‑channel I/O module like the 6416dio, the A‑Net Slot displays will
move in increments of sixteen Slots. The A‑Net Slot range display will wrap
as it reaches the end of the list of available values. The number shown in the
display corresponds to the first Slot in a group of sixteen sequential Slots,
one per channel button. The available base Slots are 1, 17, 33, and 49.
Starting Slot Displayed
A-Net Slot Range
01
Slots 1‑16
17
Slots 17‑32
33
Slots 33‑48
49
Slots 49‑64
Bank Select
Channels on the 6416dio are accessed in two banks of eight channels each;
these are always a sequential group of sixteen channels at all times. The base
Slot setting always is relative to the first channel of the range selected. Press
the
B
ank
S
ElECt
button to choose groups of eight channels at a time.
The channel activation buttons are labeled with two ranges, from 1‑8 and
from 9‑16.