Changing the sample rate, Auto/manual mode selection – Aviom 6416dio User Manual
Page 36

26
c
oNtrol
m
Aster
Press the selection button to cycle through the available sample rates.
The current sample rate for the network will be displayed on all I/O modules
in the network. Only one sample rate can be used at a time.
Changing the Sample Rate
To set or change a network‑wide sample rate from the Clock Master, use the
button below the Sample Rate LEDs to select a new rate. Pressing the Sample
Rate selector button will cycle through all available sample rates, flashing
the value for the new rate. At the same time, the LED between the Enter and
Cancel buttons will flash, indicating that pressing one of these buttons is
required to confirm and complete (or cancel) the operation.
Changing the sample rate will affect the number of available A‑Net Slots
when the sample rate changes from the 1x range (44.1/48kHz), to the 2x
range (88.2/96kHz), to the 4x range (176.4/192kHz) or vice versa.
Auto/Manual Mode Selection
The Control Master can be used to set the current network mode for the
system to Auto or Manual. As with the system‑wide sample rate, the network
mode is also a global setting.
The network mode selection controls are in the same part of the user
interface as the A‑Net Slot selection. The 6416dio has separate sections for
A‑Net Transmit and A‑Net Receive.